foxBMS-UnitTests
1.0.0
The foxBMS Unit Tests API Documentation
|
MIC plausibility checks for cell voltage and cell temperatures. More...
Go to the source code of this file.
Functions | |
STD_RETURN_TYPE_e | MIC_PlausibilityCheckVoltageMeasurementRange (const int16_t cellvoltage_mV, const MIC_PLAUSIBILITY_VALUES_s plausibleValues) |
Cell voltage measurement range plausibility check. More... | |
STD_RETURN_TYPE_e | MIC_PlausibilityCheckTempMinMax (const int16_t celltemperature_ddegC) |
Cell temperature plausibility check. More... | |
MIC plausibility checks for cell voltage and cell temperatures.
BSD 3-Clause License Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
We kindly request you to use one or more of the following phrases to refer to foxBMS in your hardware, software, documentation or advertising materials:
″This product uses parts of foxBMS®″
″This product includes parts of foxBMS®″
″This product is derived from foxBMS®″
Definition in file mic_plausibility.c.
STD_RETURN_TYPE_e MIC_PlausibilityCheckTempMinMax | ( | const int16_t | celltemperature_ddegC | ) |
Cell temperature plausibility check.
celltemperature_ddegC | cell temperature that is checked in deci °C |
Definition at line 86 of file mic_plausibility.c.
STD_RETURN_TYPE_e MIC_PlausibilityCheckVoltageMeasurementRange | ( | const int16_t | cellvoltage_mV, |
const MIC_PLAUSIBILITY_VALUES_s | plausibleValues | ||
) |
Cell voltage measurement range plausibility check.
cellvoltage_mV | cell voltage that is checked in mV |
plausibleValues | struct of type MIC_PLAUSIBILITY_VALUES_s with the plausible limits of cell voltages |
Definition at line 70 of file mic_plausibility.c.