foxBMS  1.1.1
The foxBMS Battery Management System API Documentation
mic_plausibility.c File Reference

MIC plausibility checks for cell voltage and cell temperatures. More...

#include "mic_plausibility.h"
#include "tsi.h"
Include dependency graph for mic_plausibility.c:

Go to the source code of this file.

Functions

STD_RETURN_TYPE_e MIC_PlausibilityCheckVoltageMeasurementRange (const int16_t cellvoltage_mV, const MIC_PLAUSIBILITY_VALUES_s plausibleValues)
 Cell voltage measurement range plausibility check. More...
 
STD_RETURN_TYPE_e MIC_PlausibilityCheckTempMinMax (const int16_t celltemperature_ddegC)
 Cell temperature plausibility check. More...
 

Detailed Description

MIC plausibility checks for cell voltage and cell temperatures.

SPDX-License-Identifier: BSD-3-Clause

Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:

  1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
  2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
  3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

We kindly request you to use one or more of the following phrases to refer to foxBMS in your hardware, software, documentation or advertising materials:

  • ″This product uses parts of foxBMS®″
  • ″This product includes parts of foxBMS®″
  • ″This product is derived from foxBMS®″
Author
foxBMS Team
Date
2019-01-24 (date of creation)
Updated
2021-01-15 (date of last update)
Prefix
MIC

Definition in file mic_plausibility.c.

Function Documentation

◆ MIC_PlausibilityCheckTempMinMax()

STD_RETURN_TYPE_e MIC_PlausibilityCheckTempMinMax ( const int16_t  celltemperature_ddegC)

Cell temperature plausibility check.

Parameters
celltemperature_ddegCcell temperature that is checked in deci °C

Definition at line 86 of file mic_plausibility.c.

Here is the call graph for this function:

◆ MIC_PlausibilityCheckVoltageMeasurementRange()

STD_RETURN_TYPE_e MIC_PlausibilityCheckVoltageMeasurementRange ( const int16_t  cellvoltage_mV,
const MIC_PLAUSIBILITY_VALUES_s  plausibleValues 
)

Cell voltage measurement range plausibility check.

Parameters
cellvoltage_mVcell voltage that is checked in mV
plausibleValuesstruct of type MIC_PLAUSIBILITY_VALUES_s with the plausible limits of cell voltages
Returns
STD_OK if no plausibility issue detected, otherwise STD_NOT_OK

Definition at line 70 of file mic_plausibility.c.