.. include:: ./../../../macros.txt .. include:: ./../../../units.txt .. |local_bms_master_version| replace:: ``v1.2.3`` .. |local_bms_master_identifier_short| replace:: |ti-tms570|-based |bms-master| .. |local_bms_master_identifier_full| replace:: |local_bms_master_identifier_short| |local_bms_master_version| .. _TI_TMS570_BASED_BMS_MASTER_V1_2_3: |local_bms_master_identifier_full| ================================== .. note:: The changelog for this release is found at :numref:`CHANGELOG_FOR_THE_TI_TMS570_BASED_BMS_MASTER_V1_2_3`. There are no changes that need a new documentation compared to v1.2.2, therefore see :ref:`TI_TMS570_BASED_BMS_MASTER_V1_2_2`. .. _REMOVING_THE_PULL_UP_RESISTOR_FOR_THE_PHY: ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ Removing the Pull-up Resistor for the PHY ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ In |bms-master| v1.2.3 and below, the PHY is enabled by default, which can cause issues when connecting the Ethernet cable. To avoid this, the pull-up resistors enabling the PHY should be removed. The image below shows the location of the pull-up resistors on the PCB. .. image:: ./ti-tms570lc4357-v1.2.3/img/ti-tms570lc4357-v1.2.3_pull_up_resistors.png :alt: Pull-up resistors for the PHY :name: ti-tms570lc4357-v1.2.3_pull_up_resistors