foxBMS - Unit Tests  1.3.0
The foxBMS Unit Tests API Documentation
battery_cell_cfg.c File Reference

Configuration of the battery cell. More...

#include "battery_cell_cfg.h"
Include dependency graph for battery_cell_cfg.c:

Go to the source code of this file.

Variables

const BC_LUT_s bc_stateOfChargeLookupTable []
 
const BC_LUT_s bc_stateOfEnergyLookupTable []
 
uint16_t bc_stateOfChargeLookupTableLength = sizeof(bc_stateOfChargeLookupTable) / sizeof(BC_LUT_s)
 
uint16_t bc_stateOfEnergyLookupTableLength = sizeof(bc_stateOfEnergyLookupTable) / sizeof(BC_LUT_s)
 

Detailed Description

Configuration of the battery cell.

SPDX-License-Identifier: BSD-3-Clause

Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:

  1. Redistributions of source code must retain the above copyright notice, this list of conditions and the following disclaimer.
  2. Redistributions in binary form must reproduce the above copyright notice, this list of conditions and the following disclaimer in the documentation and/or other materials provided with the distribution.
  3. Neither the name of the copyright holder nor the names of its contributors may be used to endorse or promote products derived from this software without specific prior written permission.

THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.

We kindly request you to use one or more of the following phrases to refer to foxBMS in your hardware, software, documentation or advertising materials:

  • ″This product uses parts of foxBMS®″
  • ″This product includes parts of foxBMS®″
  • ″This product is derived from foxBMS®″
Author
foxBMS Team
Date
2020-10-08 (date of creation)
Updated
2022-05-30 (date of last update)
Version
v1.3.0
Prefix
BC

This files contains battery cell lookup tables

Definition in file battery_cell_cfg.c.

Variable Documentation

◆ bc_stateOfChargeLookupTable

const BC_LUT_s bc_stateOfChargeLookupTable[]
Initial value:
= {
{4123, 100.0f}, {4088, 99.0f}, {4072, 98.0f}, {4060, 97.0f}, {4052, 96.0f}, {4045, 95.0f}, {4040, 94.0f},
{4036, 93.0f}, {4032, 92.0f}, {4028, 91.0f}, {4024, 90.0f}, {4020, 89.0f}, {4015, 88.0f}, {4009, 87.0f},
{4001, 86.0f}, {3992, 85.0f}, {3982, 84.0f}, {3972, 83.0f}, {3961, 82.0f}, {3950, 81.0f}, {3939, 80.0f},
{3927, 79.0f}, {3916, 78.0f}, {3905, 77.0f}, {3895, 76.0f}, {3885, 75.0f}, {3876, 74.0f}, {3867, 73.0f},
{3857, 72.0f}, {3849, 71.0f}, {3840, 70.0f}, {3831, 69.0f}, {3822, 68.0f}, {3812, 67.0f}, {3802, 66.0f},
{3791, 65.0f}, {3780, 64.0f}, {3769, 63.0f}, {3757, 62.0f}, {3746, 61.0f}, {3735, 60.0f}, {3724, 59.0f},
{3713, 58.0f}, {3703, 57.0f}, {3693, 56.0f}, {3683, 55.0f}, {3673, 54.0f}, {3663, 53.0f}, {3653, 52.0f},
{3644, 51.0f}, {3636, 50.0f}, {3628, 49.0f}, {3620, 48.0f}, {3613, 47.0f}, {3606, 46.0f}, {3599, 45.0f},
{3592, 44.0f}, {3586, 43.0f}, {3580, 42.0f}, {3574, 41.0f}, {3568, 40.0f}, {3563, 39.0f}, {3557, 38.0f},
{3551, 37.0f}, {3544, 36.0f}, {3538, 35.0f}, {3532, 34.0f}, {3525, 33.0f}, {3518, 32.0f}, {3510, 31.0f},
{3501, 30.0f}, {3493, 29.0f}, {3483, 28.0f}, {3472, 27.0f}, {3461, 26.0f}, {3448, 25.0f}, {3435, 24.0f},
{3422, 23.0f}, {3410, 22.0f}, {3400, 21.0f}, {3392, 20.0f}, {3383, 19.0f}, {3374, 18.0f}, {3363, 17.0f},
{3351, 16.0f}, {3334, 15.0f}, {3310, 14.0f}, {3287, 13.0f}, {3261, 12.0f}, {3234, 11.0f}, {3202, 10.0f},
{3167, 9.0f}, {3129, 8.0f}, {3087, 7.0f}, {3046, 6.0f}, {3003, 5.0f}, {2957, 4.0f}, {2901, 3.0f},
{2825, 2.0f}, {2716, 1.0f},
}

SOC lookup table

Definition at line 66 of file battery_cell_cfg.c.

◆ bc_stateOfChargeLookupTableLength

uint16_t bc_stateOfChargeLookupTableLength = sizeof(bc_stateOfChargeLookupTable) / sizeof(BC_LUT_s)

length of the SOC lookup table

Definition at line 103 of file battery_cell_cfg.c.

◆ bc_stateOfEnergyLookupTable

const BC_LUT_s bc_stateOfEnergyLookupTable[]
Initial value:
= {
{4163, 100.0f}, {4145, 99.0f}, {4131, 98.0f}, {4121, 97.0f}, {4113, 96.0f}, {4106, 95.0f}, {4101, 94.0f},
{4096, 93.0f}, {4092, 92.0f}, {4089, 91.0f}, {4085, 90.0f}, {4081, 89.0f}, {4077, 88.0f}, {4072, 87.0f},
{4066, 86.0f}, {4058, 85.0f}, {4050, 84.0f}, {4041, 83.0f}, {4032, 82.0f}, {4022, 81.0f}, {4011, 80.0f},
{4001, 79.0f}, {3991, 78.0f}, {3980, 77.0f}, {3970, 76.0f}, {3961, 75.0f}, {3951, 74.0f}, {3942, 73.0f},
{3934, 72.0f}, {3926, 71.0f}, {3918, 70.0f}, {3910, 69.0f}, {3902, 68.0f}, {3895, 67.0f}, {3887, 66.0f},
{3878, 65.0f}, {3870, 64.0f}, {3860, 63.0f}, {3851, 62.0f}, {3841, 61.0f}, {3831, 60.0f}, {3821, 59.0f},
{3811, 58.0f}, {3800, 57.0f}, {3789, 56.0f}, {3778, 55.0f}, {3767, 54.0f}, {3756, 53.0f}, {3746, 52.0f},
{3736, 51.0f}, {3726, 50.0f}, {3717, 49.0f}, {3708, 48.0f}, {3699, 47.0f}, {3691, 46.0f}, {3683, 45.0f},
{3675, 44.0f}, {3668, 43.0f}, {3661, 42.0f}, {3655, 41.0f}, {3648, 40.0f}, {3642, 39.0f}, {3636, 38.0f},
{3630, 37.0f}, {3624, 36.0f}, {3618, 35.0f}, {3612, 34.0f}, {3605, 33.0f}, {3599, 32.0f}, {3592, 31.0f},
{3585, 30.0f}, {3578, 29.0f}, {3569, 28.0f}, {3561, 27.0f}, {3551, 26.0f}, {3540, 25.0f}, {3528, 24.0f},
{3516, 23.0f}, {3504, 22.0f}, {3492, 21.0f}, {3482, 20.0f}, {3471, 19.0f}, {3460, 18.0f}, {3449, 17.0f},
{3437, 16.0f}, {3423, 15.0f}, {3406, 14.0f}, {3390, 13.0f}, {3373, 12.0f}, {3354, 11.0f}, {3332, 10.0f},
{3307, 9.0f}, {3276, 8.0f}, {3244, 7.0f}, {3212, 6.0f}, {3176, 5.0f}, {3126, 4.0f}, {3050, 3.0f},
{2929, 2.0f}, {2572, 1.0f},
}

SOE lookup table

Definition at line 85 of file battery_cell_cfg.c.

◆ bc_stateOfEnergyLookupTableLength

uint16_t bc_stateOfEnergyLookupTableLength = sizeof(bc_stateOfEnergyLookupTable) / sizeof(BC_LUT_s)

length of the SOE lookup table

Definition at line 104 of file battery_cell_cfg.c.