foxBMS  1.4.1
The foxBMS Battery Management System API Documentation
nxp_mc33775a.h
Go to the documentation of this file.
1 /**
2  *
3  * @copyright © 2010 - 2022, Fraunhofer-Gesellschaft zur Foerderung der angewandten Forschung e.V.
4  * All rights reserved.
5  *
6  * SPDX-License-Identifier: BSD-3-Clause
7  *
8  * Redistribution and use in source and binary forms, with or without
9  * modification, are permitted provided that the following conditions are met:
10  *
11  * 1. Redistributions of source code must retain the above copyright notice, this
12  * list of conditions and the following disclaimer.
13  *
14  * 2. Redistributions in binary form must reproduce the above copyright notice,
15  * this list of conditions and the following disclaimer in the documentation
16  * and/or other materials provided with the distribution.
17  *
18  * 3. Neither the name of the copyright holder nor the names of its
19  * contributors may be used to endorse or promote products derived from
20  * this software without specific prior written permission.
21  *
22  * THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
23  * AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
24  * IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
25  * DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE
26  * FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
27  * DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
28  * SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
29  * CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY,
30  * OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
31  * OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
32  *
33  * We kindly request you to use one or more of the following phrases to refer to
34  * foxBMS in your hardware, software, documentation or advertising materials:
35  *
36  * - ″This product uses parts of foxBMS®″
37  * - ″This product includes parts of foxBMS®″
38  * - ″This product is derived from foxBMS®″
39  *
40  */
41 
42 /**
43  * @file nxp_mc33775a.h
44  * @author foxBMS Team
45  * @date 2020-05-08 (date of creation)
46  * @updated 2022-10-27 (date of last update)
47  * @version v1.4.1
48  * @ingroup DRIVERS
49  * @prefix N775
50  *
51  * @brief Headers for the driver for the MC33775A monitoring chip.
52  *
53  */
54 
55 #ifndef FOXBMS__NXP_MC33775A_H_
56 #define FOXBMS__NXP_MC33775A_H_
57 
58 /*========== Includes =======================================================*/
59 #include "nxp_mc33775a_cfg.h"
60 
61 /*========== Macros and Definitions =========================================*/
62 
63 /*========== Extern Constant and Variable Declarations ======================*/
64 
65 /**
66  * Variable containing the state machine state for the MC33775A driver.
67  */
69 
70 /*========== Extern Function Prototypes =====================================*/
71 
72 /**
73  * @brief trigger function for the N775 driver state machine.
74  *
75  * This function contains the sequence of events in the N775 state machine.
76  * It must be called time-triggered, every 1ms.
77  *
78  * @param n775_state state of the N775A driver
79  *
80  */
81 extern void N775_Meas(N775_STATE_s *n775_state);
82 
83 extern bool N775_IsFirstMeasurementCycleFinished(N775_STATE_s *n775_state);
84 
85 /*========== Externalized Static Functions Prototypes (Unit Test) ===========*/
86 #ifdef UNITY_UNIT_TEST
87 /* Start test functions */
88 extern uint8_t TEST_N775_CheckReEntrance();
90 /* End test functions */
91 #endif
92 
93 #endif /* FOXBMS__NXP_MC33775A_H_ */
void TEST_N775_SetFirstMeasurementCycleFinished(N775_STATE_s *n775_state)
Definition: nxp_mc33775a.c:891
void N775_Meas(N775_STATE_s *n775_state)
trigger function for the N775 driver state machine.
Definition: nxp_mc33775a.c:251
N775_STATE_s n775_stateBase
Definition: nxp_mc33775a.c:96
bool N775_IsFirstMeasurementCycleFinished(N775_STATE_s *n775_state)
gets the measurement initialization status.
Definition: nxp_mc33775a.c:869
Header for the configuration for the MC33775A monitoring chip.