4.1.5. TI TMS570-based BMS-Master v1.2.2

Note

The changelog for this release is found at Section 4.1.1.2.

The following specifications must be met to ensure a safe and optimal work with the BMS-Master hardware.

4.1.5.4. Electrical Ratings

Description

Minimum

Typical

Maximum

Unit

Supply Voltage Clamp 30 (VSUP_30)

9

12

36

V DC

Supply Voltage Clamp 30C (VSUP_30C)

9

12

36

V DC

Contactor Continuous Current

–

–

1.8

A

Contactor Feedback Supply Voltage

–

VSUP_30

–

V

Interlock Circuit Sink Current

–

10

–

mA

Idle Supply Current at 12V DC for VSUP_30

–

215

–

mA

Idle Supply Current at 24V DC for VSUP_30

–

160

–

mA

Note

The maximum supply voltage is limited by the SBC. It is validated for limited duration for higher voltages. For further information see the SBC documentation.

4.1.5.5. Mechanical Dimensions (BMS-Master PCB only)

Description

Value

Unit

Width

120

mm

Length

200

mm

Height

13

mm

Weight

129

g