foxBMS - Unit Tests
1.1.2
The foxBMS Unit Tests API Documentation
|
plausibility checks for cell voltage and cell temperatures More...
#include "battery_cell_cfg.h"
Go to the source code of this file.
Macros | |
#define | PL_STRING_VOLTAGE_TOLERANCE_mV (3000) |
Maximum difference between pack voltage measurement from Measurement IC and current sensor. More... | |
#define | PL_CELL_VOLTAGE_TOLERANCE_mV (10) |
Maximum difference between redundant cell voltage measurement. More... | |
#define | PL_CELL_TEMPERATURE_TOLERANCE_dK (50) |
Maximum difference between redundant cell temperature measurements in deci kelvin. More... | |
#define | PL_CELL_VOLTAGE_SPREAD_TOLERANCE_mV (300) |
Maximum deviation between a single cell voltage measurement and the average cell voltage. More... | |
#define | PL_CELL_TEMPERATURE_SPREAD_TOLERANCE_dK (100) |
Maximum deviation between a single cell temperature measurement and the average cell temperature in deci kelvin. More... | |
plausibility checks for cell voltage and cell temperatures
SPDX-License-Identifier: BSD-3-Clause
Redistribution and use in source and binary forms, with or without modification, are permitted provided that the following conditions are met:
THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
We kindly request you to use one or more of the following phrases to refer to foxBMS in your hardware, software, documentation or advertising materials:
Definition in file plausibility_cfg.h.
#define PL_CELL_TEMPERATURE_SPREAD_TOLERANCE_dK (100) |
Maximum deviation between a single cell temperature measurement and the average cell temperature in deci kelvin.
Definition at line 108 of file plausibility_cfg.h.
#define PL_CELL_TEMPERATURE_TOLERANCE_dK (50) |
Maximum difference between redundant cell temperature measurements in deci kelvin.
Definition at line 88 of file plausibility_cfg.h.
#define PL_CELL_VOLTAGE_SPREAD_TOLERANCE_mV (300) |
Maximum deviation between a single cell voltage measurement and the average cell voltage.
Definition at line 98 of file plausibility_cfg.h.
#define PL_CELL_VOLTAGE_TOLERANCE_mV (10) |
Maximum difference between redundant cell voltage measurement.
Definition at line 78 of file plausibility_cfg.h.
#define PL_STRING_VOLTAGE_TOLERANCE_mV (3000) |
Maximum difference between pack voltage measurement from Measurement IC and current sensor.
Definition at line 69 of file plausibility_cfg.h.